Technical Parameters of the FKJ-B (PWM) Off - Grid Wind Solar Controller 10KW
| 
									 Type  | 
								
									 13KW-120Vdc  | 
							
| 
									 Wind turbine rated power  | 
								
									 10KW  | 
							
| 
									 Wind turbine max. power  | 
								
									 20KW  | 
							
| 
									 Solar panel power  | 
								
									 3KW  | 
							
| 
									 Battery  | 
								
									 120Vdc  | 
							
| 
									 Function  | 
								
									 Rectifier,charge, control  | 
							
| 
									 Display mode  | 
								
									 LCD  | 
							
| 
									 Display content  | 
								
									 Wind turbine voltage, wind turbine current, wind turbine power, solar panel voltage, solar panel current, solar panel power, battery voltage, charge current  | 
							
| 
									 PWM constant pressure voltage  | 
								
									 >138Vdc  | 
							
| 
									 3-phase load voltage of the wind turbine  | 
								
									 145±2Vdc  | 
							
| 
									 Recovery charging voltage of the wind turbine  | 
								
									 135±2Vdc  | 
							
| 
									 Solar controller stop charging voltage  | 
								
									 145±2Vdc  | 
							
| 
									 Solar restore charge voltage  | 
								
									 135±2Vdc  | 
							
| 
									 Low-voltage of the battery  | 
								
									 100±2Vdc  | 
							
| 
									 Self-provided connecting wire of the battery  | 
								
									 >12mm²  | 
							
| 
									 PWM fuse  | 
								
									 80A  | 
							
| 
									 Solar fuse  | 
								
									 25A  | 
							
| 
									 Charging fuse  | 
								
									 125A  | 
							
| 
									 Work environment temperature  | 
								
									 -30-60°C  | 
							
| 
									 Relative humidity  | 
								
									 <90% No condensation  | 
							
| 
									 Noise (1m)  | 
								
									 <40dB  | 
							
| 
									 Degree of protection  | 
								
									 IP20(Indoor)  | 
							
| 
									 Cooling method  | 
								
									 Forced air cooling  | 
							
| 
									 *Communication interface (optional)  | 
								
									 RS485/USB/GPRS/Ethernet  | 
							
| 
									 *Temperature compensation(optional)  | 
								
									 -4mv/°C/2V,-35°C~+80°C, Accuracy:±1°C  | 
							
| 
									 Size of the controller  | 
								
									 550*400*230 mm  | 
							
| 
									 Weight of the controller  | 
								
									 21Kg  | 
							
| 
									 Size of the load  | 
								
									 760*510*430 mm  | 
							
| 
									 Weight of the load  | 
								
									 34 Kg  | 
							
*Above parameter only for reference
1. Could be custom made to user specifications. 2, Could have solar power control subject to user demand.
						
					
	
	
	
	
	
36#, Jinghai Dong Road, Changan Town, Dongguan 523861 CHINA
	
	
 
Office:
( +86 ) -769 - 8258 6157
	
 
Cell:
( +86 ) 181 - 2297 4380
	
	
 
Email:
sales@engineer-solar.com Bob
	
 
	
	
	
 

Copyright © 2022 Engineer Solar Limited All rights reserved.